Seismic Evaluation and Retrofit of Multi-Unit Wood-Frame Buildings With Weak First Stories

Cover photo for the document: Seismic Evaluation and Retrofit of Multi-Unit Wood-Frame Buildings With Weak First Stories
Multi-unit wood-frame buildings with a weak first story represent a significant risk in highly seismic regions of the United States because of their high potential for collapse. This collapse potential is due primarily to their soft or weak first-story walls, which have often been weakened by large numbers of openings such as garages or store front windows.  FEMA P-807 addresses seismic retrofitting of weak-story wood-frame buildings in seismically active regions of the United States, with a focus on multi-family, multi-story buildings with weak first stories, and apartment buildings with tuck-under parking. These seismic retrofitting guidelines are the first to focus solely on the weak first story and to provide just enough additional strength to protect the first floor from collapse but not so much as to drive earthquake forces into the upper stories, placing them at risk of collapse. They are also the first to take into account the strength provided by existing non-structural walls, making seismic retrofitting more affordable. An electronic tool was developed as part of the project to help apply the rules and perform the calculations described in the report. The Weak Story Tool (WST) is available for download as a zip file. Note that the report contains all the data, formulas, and procedural background needed to apply the method without using the WST.
SizePublication Date
CD-ROM (with PDF, WST, and appendices) attached to back cover

  • Print Publication (Hardcopy)

    Distribution Warehouse

    Publication Number: 
    FEMA P-807
    Contact Name: 
    FEMA Distribution Center

    You can order this item from the FEMA Distribution Center. Download the Order Form and provide the resource title, FEMA publication ID #, quantity of each publication requesting, along with your name, address, zip code, and daytime phone #. Note: Some resources might have restrictions on the quantity allowed per order, per customer. Also, please review if the resource is currently backordered.

    You can order hardcopies by emailing, calling or faxing the FEMA Distribution Center using the Order Form

    Work hours for phone orders are M-F: 8:00 a.m. - 5:00 p.m., Eastern Standard Time.

    Contact Phone Number: 
    (800) 480-2520
    Fax Number: 
    (240) 699-0525
May 1, 2012