Enclosure

NFIP Policy Index

Definition/Description

Enclosures are enclosed walled in areas below the lowest floor of an elevated building. Enclosures below the BFE may only be used for building access, vehicle parking, and storage. Enclosed areas below the lowest floor must be adequately anchored, built using flood resistant building material, and any utilities or service facilities must be designed and/or located to prevent flood damage. Flood insurance coverage for enclosures below the BFE is very limited.

In A Zones, fully enclosed areas below the lowest floor must be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing the entry and exit of floodwaters. Designs must meet certain minimum criteria for openings in the enclosure walls or be certified by a registered design professional.

In V Zones, the space below the lowest floor of a building shall be free of obstruction or constructed with non-supporting breakaway walls, open wood lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. Designs to meet this criteria must be certified by a registered design professional or meet certain minimum criteria for breakaway walls.

Back To Top

NFIP Requirement

60.0 - Criteria for Land Management and Use

Back To Top

Guidance

IS-9 Managing Floodplain Development Through The National Flood Insurance Program (NFIP)

Technical Bulletin 1, Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas (FIA-TB-1)

Technical Bulletin 2, Flood-Resistant Materials Requirements for Buildings Located in Special Flood Hazard Areas (FIA-TB-2)

Technical Bulletin 6, Below-Grade Parking Requirements for Buildings Located in Special Flood Hazard Areas (FIA-TB-6)

Technical Bulletin 5, Free-Of-Obstruction Requirements For Buildings Located in Coastal High Hazard Areas (FIA-TB-5)

Technical Bulletin 9, Design and Construction Guidance for Breakaway Walls Below Elevated Coastal Buildings (FIA-TB-9)

Back To Top

Related Keywords

Breakaway Wall
Crawlspace
Flood-Resistant Material
Obstructions
Openings

Back To Top